สรุป: Discover the IEC 61347-1 Annex D Test Chamber Heating Enclosure, designed for testing thermally protected ballasts and rectifiers. This specialized enclosure ensures precise temperature control and compliance with international standards for accurate thermal protection testing.
คุณสมบัติของผลิตภัณฑ์ที่เกี่ยวข้อง:
Constructed with 25 mm thick heat-resistant material for durability and safety.
Internal test compartment dimensions of 610 mm × 610 mm × 610 mm for ample space.
Features a 75 mm heater compartment with four 300 W strip heaters for consistent heating.
Includes a 150 mm square opening with an aluminium shield for controlled air circulation.
Equipped with a thermostat for precise temperature regulation during tests.
Designed to maintain ambient temperature at 40(+0,-5) °C for accurate thermal testing.
Supports lamp controlgear in normal operating position 75 mm above the floor.
Temperature measurements taken with glass thermometers or thermocouples for reliability.
คำถามที่พบบ่อย:
What are the dimensions of the IEC 61347-1 Annex D Test Chamber?
The test compartment has internal dimensions of 610 mm × 610 mm × 610 mm, with a floor measuring 560 mm × 560 mm.
How is the temperature controlled in the test chamber?
The chamber uses four 300 W strip heaters connected in parallel and controlled by a thermostat to maintain a precise temperature of 40(+0,-5) °C.
What materials are used in the construction of the test chamber?
The entire enclosure is constructed of 25 mm thick heat-resistant material to ensure durability and safety during testing.